Hello,
Has anyone calibrated their WS-2350 with an analogue thermometer?
Mine is OK for temperatures above zero (maybe 0.1 degrees off), but when the temperature is below zero it is not OK.
I can calibrate the temperature in Cumuls. I have to give an off-set of -1 degrees and multiply it by 0,95, then it is OK again.
But then again, when the temperature is around or above zero, the temperature is too low and I have to remove the off-set.
I know it is not one of the most expensive sets, but maybe someone has ran into the same problem and found a solution for it.
Thanks in advance.
Welcome to the Cumulus Support forum.
Latest Cumulus MX V4 release 4.0.1 (build 4023) - 16 May 2024
(Note that 4.1.0 (build 4024) - 05 June 2024 remains available, but usage of this version is not recommended - particularly for Davis stations - and the included utility in this distribution for migrating to v4 is known to contain errors affecting conversion of dayfile.txt)
Latest Cumulus MX V3 release 3.28.6 (build 3283) - 21 March 2024
Legacy Cumulus 1 release 1.9.4 (build 1099) - 28 November 2014
(a patch is available for 1.9.4 build 1099 that extends the date range of drop-down menus to 2030)
Download the Software (Cumulus MX / Cumulus 1 and other related items) from the Wiki
Latest Cumulus MX V4 release 4.0.1 (build 4023) - 16 May 2024
(Note that 4.1.0 (build 4024) - 05 June 2024 remains available, but usage of this version is not recommended - particularly for Davis stations - and the included utility in this distribution for migrating to v4 is known to contain errors affecting conversion of dayfile.txt)
Latest Cumulus MX V3 release 3.28.6 (build 3283) - 21 March 2024
Legacy Cumulus 1 release 1.9.4 (build 1099) - 28 November 2014
(a patch is available for 1.9.4 build 1099 that extends the date range of drop-down menus to 2030)
Download the Software (Cumulus MX / Cumulus 1 and other related items) from the Wiki
Temperature WS-2350
-
- Posts: 6
- Joined: Wed 05 Sep 2012 12:43 pm
- Weather Station: LaCrosse WS2350
- Operating System: Windows 7
- Location: Appingedam (NL)
- Contact:
-
- Posts: 1127
- Joined: Sat 26 Feb 2011 1:58 pm
- Weather Station: Fine Offset 1080/1 & 3080
- Operating System: Windows XP SP3
- Location: SE London
Re: Temperature WS-2350
Hi,Brutus_RST wrote:I have to give an off-set of -1 degrees and multiply it by 0,95, then it is OK again.
That doesn't seem to be the correct type of correction factor because it will give a "discontinuity" around zero (or wherever you switch back to the correctly calibrated part). Can you give a few examples over the range of your "actual" and "measured" temperatures?
Probably all "good quality" stations will use a dedicated, factory-calibrated temperature sensing integrated circuit, connected by a one or two wire digital data bus (I2C, SPI, etc.) and there is nothing you can do except identify the device and fit another which might be better (or specified to a higher accuracy).
However, most of the Fine Offset models (WH 108x, etc., but apparently not 308x) use a thermistor (I don't know about the La Crosse brand) which it might be possible to calibrate (better) by adding a suitable resistor in series or parallel (or both) with the thermistor. The FO thermistor can be seen in the "Photos of the insides...." thread here.
But IMHO you're probably expecting too much accuracy from a relatively "cheap" station.
Cheers, Alan.
-
- Posts: 6
- Joined: Wed 05 Sep 2012 12:43 pm
- Weather Station: LaCrosse WS2350
- Operating System: Windows 7
- Location: Appingedam (NL)
- Contact:
Re: Temperature WS-2350
Yes, I also do think myself.But IMHO you're probably expecting too much accuracy from a relatively "cheap" station.
I do not have a list of measurements. I will keep track of this.
When I have some spare time, Ill try to see what kind of parts is used in the 2350 for measuring and try to give it an update.
If I have an update, Ill post it here.
Thanks for the reply.