Re: Inside temp problem?

Post by prodata »

Can't recall what sort of logger you've got and it may not be the logger anyway, but if the slight 'noise' on the inside temp reading coincides with loss of reception from the ISS then it might be the console trying to resynch at intervals with the ISS. For whatever reason maybe the heat output from the CPU is slightly greater during this process and hence also pushing up the temp inside the console by 0.1deg at intervals.
John Dann
Prodata Weather Systems
Littleport, East Cambs, UK
http://www.weatherstations.co.uk
RayProudfoot
Posts: 3390
Joined: Wed 06 May 2009 6:29 pm
Weather Station: Davis VP2 with Daytime FARS
Operating System: Windows XP SP3
Location: Cheadle Hulme, Cheshire, England
Contact:

Re: Inside temp problem?

Post by RayProudfoot »

Hi John,

It's the original logger from 2009 - the one before the green dot was added. Your explanation sounds very plausible. Too much of a coincidence otherwise.

@ColigWx, given John has explained the probable cause I'm not sure Davis would be bothered.
Cheers,
Ray, Cheshire.

Image
User avatar
mcrossley
Posts: 12763
Joined: Thu 07 Jan 2010 9:44 pm
Weather Station: Davis VP2/WLL
Operating System: Bullseye Lite rPi
Location: Wilmslow, Cheshire, UK
Contact:

Re: Inside temp problem?

Post by mcrossley »

I agree, the console will be switching on its receiver for much longer periods to try and resync with lost transmitter. Normally it only switches it on very briefly when a transmission is due.
RayProudfoot
Posts: 3390
Joined: Wed 06 May 2009 6:29 pm
Weather Station: Davis VP2 with Daytime FARS
Operating System: Windows XP SP3
Location: Cheadle Hulme, Cheshire, England
Contact:

Re: Inside temp problem?

Post by RayProudfoot »

Excellent! :clap: Two great minds agree. Maybe this might help others with the problem should their capacitor fail.
Cheers,
Ray, Cheshire.