Does anybody have spare indoor temperature sensor for ws1080? Mine is defective and gives 5 degrees too high readings.
Or is there any way to calibrate it (on ws display, not in cumulus)
Sensor is first one from up in the picture (under battery connectors).
It seems difficult to find part from internet.. no any type markings in it
Fine Offset have changed the internal hardware of the "WH1080" several times, including the T/H sensor. You appear to have copied the photo from the 2009 ".. Inside of..." thread. Does your sensor daughter-board (in the middle, below the barometric sensor) look exactly the same?
AFAIK, the temperature sensor is (now) part of the Temperature/Humidity sensor so you also need to determine if the Relative Humidity is anywhere near "correct". Earlier consoles had the problem that the battery/USB power-switching relay heated up the inside of the console slightly, but later versions do not use a relay. If your "temperature sensor" still uses a thermistor (bead) then you might "adjust" the temperature with a replacement, or with a series or parallel resistor, as appropriate.
BTW, where in the World are you located, as this may affect any spares/shipping solution?
Hi Alan, thanks for response and sorry for a late reply.
My station is indeed little different. It has temp sensor board in different side of main board. There is hole in main board where sensor's eye comes through. The little sensor board looks similar so I thought that it is interchangeable..