Welcome to the Cumulus Support forum.

Latest Cumulus MX V3 release 3.28.6 (build 3283) - 21 March 2024

Cumulus MX V4 beta test release 4.0.0 (build 4019) - 03 April 2024

Legacy Cumulus 1 release 1.9.4 (build 1099) - 28 November 2014
(a patch is available for 1.9.4 build 1099 that extends the date range of drop-down menus to 2030)

Download the Software (Cumulus MX / Cumulus 1 and other related items) from the Wiki

Search found 674 matches

by laulau
Mon 11 May 2020 10:18 am
Forum: Davis VP/VP2/Vue
Topic: VP2 setup
Replies: 5
Views: 1648

Re: VP2 setup

All the things that are in the console setup mode.
by laulau
Sat 09 May 2020 3:05 pm
Forum: Homebuilt
Topic: Davis VP2 Relay Device
Replies: 102
Views: 125732

Re: Davis VP2 Relay Device

Ok, let me know when the new code is available. In the meantime i have tested again, and my VP2 is catching the relay data with the solar included :D It works with a Nano and a HOPERF RFM69HW-868S2.(older model) The IISRx sketch isn't receiving the relay data :x it's a Pro Mini with a RFM69HCW-??? ....
by laulau
Sat 09 May 2020 8:16 am
Forum: Davis VP/VP2/Vue
Topic: Software switch
Replies: 5
Views: 1592

Re: Software switch

Weerhaas wrote: Sat 09 May 2020 7:36 am Maybe you can use Virtual Serial Ports Emulator from Eterlogic for Windows.
Free for 32 bits.
VSPE works fine when you have an unidirectional communication station that only send data.
For VP2 a bidirectionnel communication is needed so i don't think you can share the VP serial port.
by laulau
Fri 08 May 2020 5:57 pm
Forum: Davis VP/VP2/Vue
Topic: Software switch
Replies: 5
Views: 1592

Software switch

Hi,
Could someone point me how to switch from CumulusMX to Weatherlink and back so that the data are up to date in both software ?
Thanks
by laulau
Fri 08 May 2020 5:46 pm
Forum: Davis VP/VP2/Vue
Topic: VP2 setup
Replies: 5
Views: 1648

VP2 setup

Hi,
Is there an alternative to Weathelink software to do the (complete) station setup ?
Thanks
by laulau
Fri 08 May 2020 12:30 am
Forum: Homebuilt
Topic: Davis VP2 Relay Device
Replies: 102
Views: 125732

Re: Davis VP2 Relay Device

Despite ISSRx.ino sketch doesn't receive the TX_ID 2 data i gave a go on my VP2 and :o some packets were catched. VP2 doesn't stay synchronised with station 3 and data from my wind transmitter (station 2) were also lost. I think i have to change the TX parameters on the fly and see what happens, but...
by laulau
Thu 07 May 2020 4:49 pm
Forum: Cumulus MX Current (releases since b3043)
Topic: ImportCumulusFile.php 4.0
Replies: 9
Views: 1763

Re: ImportCumulusFile.php 4.0

I have the same error !
Perhaps it's because older entry have less data ?
SQL guru help needed :oops:
by laulau
Thu 07 May 2020 2:37 pm
Forum: Cumulus 1 (No longer being developed)
Topic: Cumulus1 Installation Files?
Replies: 7
Views: 2166

Re: Cumulus1 Installation Files?

PM sent with link
by laulau
Thu 07 May 2020 1:08 pm
Forum: Cumulus MX Development Suggestions (rejected / resolved)
Topic: CLOSED as IMPLEMENTED: Feels Like (from 3.6.10) and Humidex (from 3.7.0)
Replies: 25
Views: 5957

Re: Feels Like (in 3.6.0) and Humidex (not implemented)

I'm not sure i can use the MX SQL internal facilities as my db isn't hosted locally.
My db is on OVH which host my website.
by laulau
Thu 07 May 2020 11:31 am
Forum: Homebuilt
Topic: Davis VP2 Relay Device
Replies: 102
Views: 125732

Re: Davis VP2 Relay Device

I'm a little lost :
rssi is received signal strength indication.
What is fei and which value should we have ?
Do you have an US frequency system ?
by laulau
Thu 07 May 2020 10:47 am
Forum: Cumulus MX Development Suggestions (rejected / resolved)
Topic: CLOSED as IMPLEMENTED: Feels Like (from 3.6.10) and Humidex (from 3.7.0)
Replies: 25
Views: 5957

Re: Feels Like (in 3.6.0) and Humidex (not implemented)

I'm running MX v3.6.0 but i dont't have 'feels like ' in realtime.txt ? :o
It's ok in dayfile and monthlog .
Strange isn't it ?
by laulau
Thu 07 May 2020 12:21 am
Forum: Homebuilt
Topic: Davis VP2 Relay Device
Replies: 102
Views: 125732

Re: Davis VP2 Relay Device

Hi Mark, I've done a modified version of RelayRxTx and include solar data.(Arduino nano with RFM69HW) The serial output show that packets are transmitted but VP2 console don't get them. I run ISSRx.ino sketch on an other arduino equiped with RFM69 to decode the transmission. I get the station0 and s...
by laulau
Wed 06 May 2020 2:34 pm
Forum: Cumulus MX Development Suggestions (rejected / resolved)
Topic: CLOSED as IMPLEMENTED: Feels Like (from 3.6.10) and Humidex (from 3.7.0)
Replies: 25
Views: 5957

Re: Feels Like (in 3.6.0) and Humidex (not implemented)

Hi,
In my realtime table the last clumn is "RG11rain" :o
Don't remember why :oops: