Welcome to the Cumulus Support forum.
Latest Cumulus MX V3 release 3.28.6 (build 3283) - 21 March 2024
Cumulus MX V4 beta test release 4.0.0 (build 4018) - 28 March 2024
Legacy Cumulus 1 release v1.9.4 (build 1099) - 28 November 2014 (a patch is available for 1.9.4 build 1099 that extends the date range of drop-down menus to 2030)
Download the Software (Cumulus MX / Cumulus 1 and other related items) from the Wiki
Latest Cumulus MX V3 release 3.28.6 (build 3283) - 21 March 2024
Cumulus MX V4 beta test release 4.0.0 (build 4018) - 28 March 2024
Legacy Cumulus 1 release v1.9.4 (build 1099) - 28 November 2014 (a patch is available for 1.9.4 build 1099 that extends the date range of drop-down menus to 2030)
Download the Software (Cumulus MX / Cumulus 1 and other related items) from the Wiki
Search found 38 matches
- Fri 02 Apr 2010 9:43 am
- Forum: Fine Offset/EasyWeather
- Topic: Outside Humidity not going above 92%
- Replies: 5
- Views: 2484
- Sun 07 Mar 2010 7:16 pm
- Forum: Fine Offset/EasyWeather
- Topic: Fine Offset anemometer repair
- Replies: 3
- Views: 1945
Re: Fine Offset anemometer repair
Thank you Daniel
Very useful and nice.
Stefano
Very useful and nice.
Stefano
- Wed 17 Feb 2010 10:54 pm
- Forum: Cumulus 1 (No longer being developed)
- Topic: I can't edit anything...
- Replies: 5
- Views: 1978
Re: I can't edit anything...
Thank you Dave, I've found the data files where you wrote. Thanks for italian also
...what about the file cumulus.s3db?
That's the last question
Have a good night.
Stefano
...what about the file cumulus.s3db?
That's the last question
Have a good night.
Stefano
- Wed 17 Feb 2010 10:34 pm
- Forum: Cumulus 1 (No longer being developed)
- Topic: I can't edit anything...
- Replies: 5
- Views: 1978
Re: I can't edit anything...
Vista Daji; in the past, with previous versions of cumulus, I remember that ini files was present.
I'm not able to understand where data files are stored...
Many thanks and sorry for my poor english.
Stefano
I'm not able to understand where data files are stored...
Many thanks and sorry for my poor english.
Stefano
- Wed 17 Feb 2010 9:53 pm
- Forum: Cumulus 1 (No longer being developed)
- Topic: I can't edit anything...
- Replies: 5
- Views: 1978
I can't edit anything...
I haven't today.ini, yesterday.ini ... I have to correct yesterday rain (over 350 mm) but I can't find any file to edit.
After deleting the cumulus directory and reinstalling it ... I can't find ini files.
Thanks.
Stefano
After deleting the cumulus directory and reinstalling it ... I can't find ini files.
Thanks.
Stefano
- Tue 20 Oct 2009 9:28 am
- Forum: Fine Offset/EasyWeather
- Topic: Outside Relative Humidity on WH1080
- Replies: 62
- Views: 29446
Re: Outside Relative Humidity on WH1080
I have three weather stations Davis VP2 close to me, within the radius of 3 km. After the last modification, the easiest to do, my station is aligned with these also for u.r. . For my station the gap was not linear, so the correction made by cumulus has been good for high values of moisture but bad ...
- Thu 17 Sep 2009 6:35 am
- Forum: Fine Offset/EasyWeather
- Topic: Outside Relative Humidity on WH1080
- Replies: 62
- Views: 29446
Re: Outside Relative Humidity on WH1080
Hi guys,
today the humidity has reached 99%, so I can say definitively that the solution of distancing the sensor from printed board, without resistors, is good.
Bye.
Stefano
today the humidity has reached 99%, so I can say definitively that the solution of distancing the sensor from printed board, without resistors, is good.
Bye.
Stefano
- Sun 09 Aug 2009 5:36 am
- Forum: Fine Offset/EasyWeather
- Topic: Outside Relative Humidity on WH1080
- Replies: 62
- Views: 29446
Re: Outside Relative Humidity on WH1080
Hi all, FINALLY SOLVED! :D I've removed all the resistors, I experienced that the best way to resolve the problem about the humidity sensor is to move the sensor from the printed board. I've do it with two short (each about 2 cm long) between the sensor and the printed board. Care with the solderer....
- Thu 16 Apr 2009 7:43 am
- Forum: Fine Offset/EasyWeather
- Topic: Outside Relative Humidity on WH1080
- Replies: 62
- Views: 29446
Re: Outside Relative Humidity on WH1080
Breaking news :D To have reliable results I've set the potentiometer to max resistance, so I need about totally 15 MOhm . I suppose that the upper shift of r.h. is not linear for all the values of r.h. Other thing, partially inserting the shield on the thermohygrometric sensor, the temperature recor...
- Tue 14 Apr 2009 7:45 am
- Forum: Fine Offset/EasyWeather
- Topic: Pro Weather Station - TP1080WC
- Replies: 9
- Views: 5886
Re: Pro Weather Station - TP1080WC
Next step, form me, is to reduce lenght of the wire, if possible, or to change the total inductance/capacitance of this (by changing the route of the cable, for example).
Last but not least, try to clean the connector with an appropriate product (easy to find in electronics shops).
Bye.
Last but not least, try to clean the connector with an appropriate product (easy to find in electronics shops).
Bye.
- Sat 11 Apr 2009 9:22 pm
- Forum: Fine Offset/EasyWeather
- Topic: Pro Weather Station - TP1080WC
- Replies: 9
- Views: 5886
Re: Pro Weather Station - TP1080WC
Batteries can be ko even if new, change them
- Fri 10 Apr 2009 7:28 am
- Forum: Fine Offset/EasyWeather
- Topic: Pro Weather Station - TP1080WC
- Replies: 9
- Views: 5886
Re: Pro Weather Station - TP1080WC
Hi Jsauerii, first of all...I try changing the batteries.
- Wed 08 Apr 2009 6:03 pm
- Forum: Fine Offset/EasyWeather
- Topic: Pro Weather Station - TP1080WC
- Replies: 9
- Views: 5886
Re: Pro Weather Station - TP1080WC
Are you using alkaline or rechargeable batteries?
- Mon 06 Apr 2009 9:18 pm
- Forum: Fine Offset/EasyWeather
- Topic: Outside Relative Humidity on WH1080
- Replies: 62
- Views: 29446
Re: Outside Relative Humidity on WH1080
At the moment I haven't photos. Care...my solder is too warm for that printed circuit, resulting in little damages (printed circuit damaged where the sensor is soldered). In the first stage I've soldered two thin wires over the printed circuit , the resistor with the potentiometer (flying) and the t...
- Sun 05 Apr 2009 2:53 pm
- Forum: Fine Offset/EasyWeather
- Topic: Outside Relative Humidity on WH1080
- Replies: 62
- Views: 29446
Re: Outside Relative Humidity on WH1080
Is a linear potentiometer, (with a 5.8 MOhm resistor the correction was too strong, so I've tried a greater resistance across the sensor pins). With the ohmmeter, the resistance of the potentiomenter is about 8MOhm, so,the total resistance is about 14MOhm. Now I'm testing. Have a nice sunday. Stefano